Table 1. Clock Generation Register Overview
Register Description Comments
PLL
PLL_STATUS PLL status
Arm_PLL_CTRL CPU PLL control
  • Control registers include:
    • Reset, power-down, bypass
    • Divisor(s)
  • Configuration registers include:
    • PLL control parameters (see Table 1)
Arm_PLL_CFG CPU PLL configuration
DDR_PLL_CTRL DDR PLL control
DDR_PLL_CFG DDR PLL configuration
IO_PLL_CTRL I/O PLL control
IO_PLL_CFG I/O PLL configuration
CPU, DDR and Interconnect
Arm_CKL_CTRL CPU clock control
CLK_621_TRUE Select CPU clock frequency ratio 6:2:1 or 4:2:1
DDR_CLK_CTRL DDR clock control
APER_CLK_CTRL AMBA peripheral clock control
TOPSW_CLK_CTRL Top-level switch clock control
PL Clocks
FPGA{3:0}_CLK_CTRL PS to PL output clock control
FPGA{3:0}_THR_{CTRL, CNT, STA} PS to PL output clock throttle control, count and status
I/O Peripheral Clocks
GEM{1, 0}_RCLK_CTRL Gigabit Ethernet RX clock control
  • DIVISOR bit field (one or two parameters, depending on the peripheral)
  • Clock enable active control
GEM{1, 0}_CLK_CTRL Gigabit Ethernet ref clock control
SMC_CLK_CTRL SMC ref clock control
LQSPI_CLK_CTRL Quad-SPI ref clock control
SDIO_CLK_CTRL SDIO ref clock control
UART_CLK_CTRL UART ref clock control
SPI_CLK_CTRL SPI ref clock control
CAN_CLK_CTRL CAN ref clock control
CAN_MIOCLK_CTRL CAN comm port clock control
System Debug Clocks
DBG_CLK_CTRL CoreSight SoC trace clk control
PCAP_CLK_CTRL PCAP clock control This controls the frequency and enable of the PCAP_2X clock for the DevC module.