Field Name Bits Type Reset Value Description
StopTrig 13 rw 0x0 Stop the formatter when a Trigger Event has been observed.
StopFl 12 rw 0x0 Stop the formatter when a flush has completed (return of AFREADYS). This forces the FIFO to drain off any part-completed packets. Setting this bit enables this function but this is clear on reset (disabled).
reserved 11 ro 0x0 Reserved
TrigFl 10 rw 0x0 Indicate a trigger on Flush completion (AFREADYS being returned).
TrigEvt 9 rw 0x1 Indicate a trigger on a Trigger Event.
TrigIn 8 rw 0x0 Indicate a trigger on TRIGIN being asserted.
reserved 7 ro 0x0 Reserved
FOnMan 6 rw 0x0 Manually generate a flush of the system. Setting this bit causes a flush to be generated. This is cleared when the flush has been serviced. This bit is clear on reset.
FOnTrig 5 rw 0x0 Generate flush using Trigger event. Set this bit to cause a flush of data in the system when a Trigger Event occurs. This bit is clear on reset.
FOnFlIn 4 rw 0x0 Generate flush using the FLUSHIN interface. Set this bit to enable use of the FLUSHIN connection. This bit is clear on reset.
reserved 3:2 ro 0x0 Reserved
EnFCont 1 rw 0x0 Continuous Formatting. Continuous mode in the ETB corresponds to normal mode with the embedding of triggers. Can only be changed when FtStopped is HIGH. This bit is clear on reset.
EnFTC 0 rw 0x0 Enable Formatting. Do not embed Triggers into the formatted stream. Trace disable cycles and triggers are indicated by TRACECTL, where fitted. Can only be changed when FtStopped is HIGH. This bit is clear on reset.