Register DRAM_param_reg1 Details - Register DRAM_param_reg1 Details - 1.15 English - UG585

Zynq 7000 SoC Technical Reference Manual (UG585)

Document_ID
UG585
Release_Date
2026-02-06
Version
1.15 English
Field Name Bits Type Reset Value Description
reg_ddrc_t_cke 31:28 rw 0x3

Minimum number of cycles of CKE HIGH/LOW during power down and self refresh.

DDR2 and DDR3: Set this to tCKE value.

LPDDR2: Set this to the larger of tCKE or tCKESR.

Unit: clocks.

reg_ddrc_t_ras_min 26:22 rw 0x14

tRAS(min) - Minimum time between activate and precharge to the same bank.

Unit: clocks

DRAM related.

Default value is set for DDR3.

reg_ddrc_t_ras_max 21:16 rw 0x1B

tRAS(max) - Maximum time between activate and precharge to same bank. Maximum time that a page can be kept open (spec is 70 us). If this is zero then the page is closed after each transaction.

Unit: Multiples of 1024 clocks

DRAM related.

reg_ddrc_t_faw 15:10 rw 0x12 tFAW - At most 4 banks must be activated in a rolling window of tFAW cycles. Unit: clocks. DRAM Related.
reg_ddrc_powerdown_to_x32 9:5 rw 0x6 After this many clocks of NOP or DESELECT the controller will put the DRAM into power down. This must be enabled in the Master Control Register. Unit: Multiples of 32 clocks.
reg_ddrc_wr2pre 4:0 rw 0x19

Minimum time between write and precharge to same bank

DDR and DDR3: WL + BL/2 + tWR

LPDDR2: WL + BL/2 + tWR + 1

Unit: Clocks

Where,

WL: write latency.

BL: burst length. This must match the value programmed in the BL bit of the mode register to the DRAM. BST is not supported at present.

tWR: write recovery time. This comes directly from the DRAM specs.