| Field Name | Bits | Type | Reset Value | Description |
|---|---|---|---|---|
| reg_ddrc_t_cke | 31:28 | rw | 0x3 |
Minimum number of cycles of CKE HIGH/LOW during power down and self refresh. DDR2 and DDR3: Set this to tCKE value. LPDDR2: Set this to the larger of tCKE or tCKESR. Unit: clocks. |
| reg_ddrc_t_ras_min | 26:22 | rw | 0x14 |
tRAS(min) - Minimum time between activate and precharge to the same bank. Unit: clocks DRAM related. Default value is set for DDR3. |
| reg_ddrc_t_ras_max | 21:16 | rw | 0x1B |
tRAS(max) - Maximum time between activate and precharge to same bank. Maximum time that a page can be kept open (spec is 70 us). If this is zero then the page is closed after each transaction. Unit: Multiples of 1024 clocks DRAM related. |
| reg_ddrc_t_faw | 15:10 | rw | 0x12 | tFAW - At most 4 banks must be activated in a rolling window of tFAW cycles. Unit: clocks. DRAM Related. |
| reg_ddrc_powerdown_to_x32 | 9:5 | rw | 0x6 | After this many clocks of NOP or DESELECT the controller will put the DRAM into power down. This must be enabled in the Master Control Register. Unit: Multiples of 32 clocks. |
| reg_ddrc_wr2pre | 4:0 | rw | 0x19 |
Minimum time between write and precharge to same bank DDR and DDR3: WL + BL/2 + tWR LPDDR2: WL + BL/2 + tWR + 1 Unit: Clocks Where, WL: write latency. BL: burst length. This must match the value programmed in the BL bit of the mode register to the DRAM. BST is not supported at present. tWR: write recovery time. This comes directly from the DRAM specs. |