The UART flow control signals, DTR and RTS are generated by the UART controller.

  • The RTS flow control signal is used to signal for RX (ready to send signal to the attached terminal).
  • The DTR flow control signal indicates the status of the UART controller (data terminal ready).

The DTR and RTS can be controlled manually by software or automatically by the controller.

  • In automatic mode, the modem control unit asserts and de-asserts the RTS and DTR signals.
  • In manual mode, software controls the RTS and DTR signals using uart.Modem_ctrl_reg0.

uart.Modem_ctrl_reg0:

  • [DTR]: Data Terminal Ready output signal
  • [RTS]: Request to Send output signal
  • [FCM]: Select Automatic or Manual flow control.

uart.Modem_sts_reg0:

  • [DCTS]: Delta Clear To Send (input) status
  • [DDSR]: Delta Data Set Ready (input) status
  • [TERI]: Trailing-edge Ring Indicator (input) status
  • [DDCD]: Delta Data Carrier Detect (input) status