PS–PL AXI Interfaces - PS–PL AXI Interfaces - 1.15 English - UG585

Zynq 7000 SoC Technical Reference Manual (UG585)

Document_ID
UG585
Release_Date
2026-02-06
Version
1.15 English

The PS side of the AXI interfaces are based on the AXI 3 interface specification. Each interface consists of multiple AXI channels. The interfaces are summarized in the following table. Over a thousand signals are used to implement these nine PL AXI interfaces.

Note: The PL level shifters must be enabled via LVL_SHFTR_EN before PL logic communication can occur, refer to Clocks and Resets.
Table 1. PL AXI Interfaces
Interface Name Interface Description Master Slave Signals
M_AXI_GP0 General Purpose (AXI_GP) PS PL

Interconnect describes each of these interfaces.

The AXI signals are listed individually in PS-PL AXI Interface Signals.

The AXI_ACP interface is also described in multiple places in Application Processing Unit, including PL Co-processing Interfaces.

The PS interconnect is shown in Figure 1.

M_AXI_GP1 PS PL
S_AXI_GP0 General Purpose (AXI_GP) PL PS
S_AXI_GP1 PL PS
S_AXI_ACP Accelerator Coherency Port, cache-coherent transaction (ACP) PL PS
S_AXI_HP0 High Performance ports (AXI_HP) with read/write FIFOs and two dedicated memory ports on DDR controller and a path to the OCM. The AXI_HP interfaces are known also as AFI. PL PS
S_AXI_HP1 PL PS
S_AXI_HP2 PL PS
S_AXI_HP3 PL PS