The PS side of the AXI interfaces are based on the AXI 3 interface specification. Each interface consists of multiple AXI channels. The interfaces are summarized in the following table. Over a thousand signals are used to implement these nine PL AXI interfaces.
Note: The PL level shifters must be enabled via LVL_SHFTR_EN
before PL logic communication can occur, refer to Clocks and Resets.
| Interface Name | Interface Description | Master | Slave | Signals |
|---|---|---|---|---|
| M_AXI_GP0 | General Purpose (AXI_GP) | PS | PL |
Interconnect describes each of these interfaces. The AXI signals are listed individually in PS-PL AXI Interface Signals. The AXI_ACP interface is also described in multiple places in Application Processing Unit, including PL Co-processing Interfaces. The PS interconnect is shown in Figure 1. |
| M_AXI_GP1 | PS | PL | ||
| S_AXI_GP0 | General Purpose (AXI_GP) | PL | PS | |
| S_AXI_GP1 | PL | PS | ||
| S_AXI_ACP | Accelerator Coherency Port, cache-coherent transaction (ACP) | PL | PS | |
| S_AXI_HP0 | High Performance ports (AXI_HP) with read/write FIFOs and two dedicated memory ports on DDR controller and a path to the OCM. The AXI_HP interfaces are known also as AFI. | PL | PS | |
| S_AXI_HP1 | PL | PS | ||
| S_AXI_HP2 | PL | PS | ||
| S_AXI_HP3 | PL | PS |