The SMC is based on Arm's PL353 Primecell core and is hard-coded such that controller 0 can operate in SRAM/NOR mode and controller 1 can operate in NAND flash mode. The SRAM/NOR or NAND interface can be used in a system, but not both. The SRAM/NOR interface does not support PSRAM. The NAND flash controller does not support wear leveling.

When referencing Arm documentation, for programming and other purposes, refer to the implementation notes in the following table.

Table 1. SMC PL353 Implementation Notes
Parameter Value Design Notes
Chip Selects (Interface 0) 2 SRAM/NOR interface chip selects operate independently.
Chip Select (Interface 1) 1 NAND flash interface chip select
NAND flash mode data width 16 Data width can be 8 or 16 bits
SRAM mode data width 8 Data width is 8 bits.
System interface bus width 32 AXI
System interface clock rate ~ CPU_1x (1/6th or 1/4th the CPU clock frequency)
Command FIFO depth 8 Maximum supported depth on both interfaces
Read data word FIFO depth 16 Maximum supported depth on both interfaces
Write data word FIFO depth 16 Maximum supported depth on both interfaces
ECC support Yes 1-bit ECC hardware with assistance from software
ECC Extra Block Yes Supported
TCCS Yes This field indicates the minimum change column setup time (TCCS) in nanoseconds. After issuing a Change Read Column command, the host shall not read data until a minimum of TCCS time has elapsed. After issuing a change write column command including all column address cycles, the host shall not write data until a minimum of TCCS time has elapsed. The value of TCCS shall always be longer than or equal to TWHR and TADL when the source synchronous data interface is supported.
Note: Arm's PL353 documentation has a different timing naming convention (used in the SET_CYCLES register) than the ONFI Specification 1.0.