PL General Purpose User Resets - PL General Purpose User Resets - 1.15 English - UG585

Zynq 7000 SoC Technical Reference Manual (UG585)

Document_ID
UG585
Release_Date
2026-02-06
Version
1.15 English

There are four separate reset signals, FCLKRESETN[3:0], routed to the PL which could be used as general purpose reset signals for PL logic. These reset signals are not removed until the PS is out of its boot sequence and user code de-asserts them. They are controllable by the slcr.FPGA_RST_CTRL register. SLCR.FPGA_RST_CTRL. PL logic connecting to the PS must not be reset when active bus transactions exist, because uncompleted transactions could be left pending in the PS.

The reset signal is loosely associated with the FCLK of the same number, however, the timing is such that it must be considered an asynchronous reset to the PL. If the user requires a synchronized reset, the user must synchronize it themselves in the PL. (The FCLK needs to be toggling for the reset to propagate out of the PS.)