I/O mode has different modes of flow control during data transfer. The user can select between automatic and manual mode, controlled by config_reg.MANSTARTEN (Man_start_com). In Manual mode, the user can further select manual or automatic chip select with Config_reg.SSFORCE (Manaual_CS). Asserting chip select signals the beginning of a command sequence on MIO. Immediately following the CS assertion, serial data on D0 is interpreted as command by the flash memory.

In automatic mode, the entire transmission sequence, including control of chip select is done in hardware. No software intervention is required. The transmission starts as soon as data is pushed into the TxFIFO via writing to TXD, chip select automatically becomes active. Data transmission ends when the TxFIFO is empty and chip select automatically becomes inactive. In this mode, to carry out continuous data transfer, software must be able to keep up with supplying data to the TxFIFO at a rate equal or higher than the rate of data movement on the MIO. This can be difficult because reading from RXD and writing to TXD occurs at the APB clock rate.

In Manual mode, the user controls the start of data transmission. In this case, software either writes the entire transmission sequence to the TxFIFO or until the TxFIFO is full. Upon writing of the Man_start_en bit, the controller takes over, asserts CS, shifts data out of the TxFIFO and into the RxFIFO, controls the input/ouput state of the MIO as appropriate, and terminates the sequence when the TxFIFO is empty by de-asserting CS. The maximum number of bytes per command sequence in this mode is limited by the depth of the TxFIFO of 252 bytes.

In manual mode, the user can further choose to control the chip select in addition to controlling the start of transmission. Software again writes the transmission sequence to the TxFIFO starting with the command until the TxFIFO is full. Software then asserts CS, followed by manual start. The hardware takes over. However, CS is not de-asserted when the TxFIFO becomes empty. Software can fill the TxFIFO again with the appropriate data to continue the previous command. This method removes the limit on the number of bytes per command sequence and can be used effectively for large data transfers. On completion of the command sequence, the software de-asserts CS by writing to the Manual_CS bit.