Bit 1 of the L2 Controller Power Control register enables the dynamic clock gating feature within the controller. If this feature is enabled, the cache controller stops its clock when it is idle for 32 clock cycles. The controller stops the clock until there is a transaction on its slave interface from the SCU. If this interface detects a transaction, it restarts its clock and accepts the new transaction with two to three cycles of delay.