The following table lists the major datapaths used by the PS interconnect.
Table 1. Interconnect Datapaths
Source Destination Type Clock at source Clock at destination Sync or Async 1 Data width R/W Request Capability Advanced QoS
CPU SCU AXI CPU_6x4x CPU_6x4x Sync 64 7, 12 -
AXI_ACP SCU AXI SAXIACPACLK CPU_6x4x Async 64 7, 3 -
AXI_HP FIFO AXI SAXIHPnACLK DDR_2x Async 32/64 14-70, 8-32 2 -
S_AXI_GP Master interconnect AXI SAXIGPnACLK CPU_2x Async 32 8, 8 -
DevC Master interconnect AXI CPU_1x CPU_2x Sync 32 8, 4 -
DAP Master interconnect AHB CPU_1x CPU_2x Sync 32 1, 1 -
AHB masters Central interconnect AXI CPU_1x CPU_2x Sync 32 8, 8 X
DMA controller Central interconnect AXI CPU_2x CPU_2x Sync 64 8, 8 X
Master interconnect Central interconnect AXI CPU_2x CPU_2x Sync 64 - -
FIFO Memory interconnect AXI DDR_2x DDR_2x Sync 64 8, 8 -
SCU L2 Cache AXI CPU_6X4x CPU_6x4x Sync 64 8, 3 -
Memory interconnect OCM interconnect AXI DDR_2x CPU_2x Async 64 - -
Central interconnect OCM interconnect AXI CPU_2x CPU_2x Sync 64 - -
L2 Cache Slave interconnect AXI CPU_6x4x CPU_2x Sync 64 8, 8 -
Central interconnect Slave interconnect AXI CPU_2x CPU_2x Sync 64 - -
SCU On-chip RAM AXI CPU_6x4x CPU_2x Sync 64 4, 4 -
OCM interconnect On-chip RAM AXI CPU_2x CPU_2x Sync 64 4, 4 -
Slave interconnect APB slave APB CPU_2x CPU_1x Sync 32 1, 1 -
Slave interconnect AHB slave AXI CPU_2x CPU_1x Sync 32 4, 4 -
Slave interconnect AXI_GP AXI CPU_2x MAXIGPnACLK Async 32 8, 8 -
L2 cache DDR controller AXI CPU_6x4x DDR_3x Async 64 8, 8 X
Central interconnect DDR controller AXI CPU_2x DDR_3x Async 64 8, 8 -
Memory interconnect DDR controller AXI DDR_2x DDR_3x Async 64 8, 8 -
Slave interconnect GPV 3 CPU_2x (multiple) - - - -
  1. Each asynchronous path includes an asynchronous bridge for clock domain crossing.
  2. Burst-length dependent (see AXI_HP Interfaces).
  3. The path from the slave interconnect to GPV is an internal path within the entire interconnect structure. When accessing GPV, ensure that all clocks are on.