Clock Throttle - Clock Throttle - 1.15 English - UG585

Zynq 7000 SoC Technical Reference Manual (UG585)

Document_ID
UG585
Release_Date
2026-02-06
Version
1.15 English

Each of the four PL clocks includes logic to start and stop the clock and to assist with PL design debug and co-simulation. The clock throttle behavior is controlled by software and the trigger input signal from the PL. The clock throttle functions include:

  • Start/stop clock under software control
  • Run clock for a pre-programmed number of pulses
  • Run clock and use PL logic to pause the clock pulses

Each clock throttle has a 16-bit counter that is programmed for the number of clock pulses to generate. For a continuous clock output, write a 0 to the counter, which is the default value. The current count can be read by software. The counting and clock pulses can be paused by the PL logic using the FCLKCLKTRIGxN input signal from the PL. The software can re-start the clocking by writing to the PL clock control register.

Table 1. PL Clock Throttle Input Signal
Signal Name I/O Description
FCLKCLKTRIGxN I The PL clock trigger signal is an input from the PL logic and is used to halt (pause) the PL clock when counting a programmed number of clock pulses. The halt mode is entered by the rising edge (logic 0 to logic 1) of the FCLKCLKTRIGxN signal. This signal can be asserted asynchronously to the FCLK and all other signals. This pin has no affect when the clock is running continuously, [LAST_CNT] = 0.