Calibration - Calibration - 1.15 English - UG585

Zynq 7000 SoC Technical Reference Manual (UG585)

Document_ID
UG585
Release_Date
2026-02-06
Version
1.15 English

DDR3/DDR3L devices provide ODT calibration via the ZQCL and ZQCS commands. The ZQCL (ZQ calibration long) command is issued as part of the DRAM initialization procedure and is used for initial calibration, which takes about 512 DDR_3x clock cycles. The ZQCS (ZQ calibration short) is subsequently issued automatically by the DDRC for minor calibration adjustments. A typical ZQCS interval is 100 ms.

DDR2 (and LPDDR2) devices do not provide ODT calibration.