There are two controller area network (CAN) reference clocks: CAN0_REF_CLK and CAN1_REF_CLK. Both clocks share the same PLL source selection and dividers as shown in the following figure. Each clock has independent alternate source selection (MIO pin or the clock generator), and independent clock gates. These clocks are used for the I/O interface side of the CAN peripherals.
Figure 1. CAN Clock Generation