Branch Prediction - Branch Prediction - 1.15 English - UG585

Zynq 7000 SoC Technical Reference Manual (UG585)

Document_ID
UG585
Release_Date
2026-02-06
Version
1.15 English

To minimize the branch penalty in its highly pipelined CPU, the Cortex-A9 implements both static and dynamic branch prediction. Static branch prediction is provided by the instructions and is decided during compilation. Dynamic branch prediction uses the outcome of the previous executions of a specific branch to determine whether the branch should be taken or not. The dynamic branch prediction logic employs a global branch history buffer (GHB) which is a 4,096 entry table holding 2-bit prediction information for specific branches and is updated every time a branch gets executed.

The branch execution and the overall instruction throughput also benefit greatly from the implementation of a branch target address cache (BTAC) which holds the target addresses of the recent branches. This 512-entry address cache is organized as 2-way × 256 entries and provides the target address for a specific branch to the pre-fetch unit before the actual target address is generated based on the calculation of the effective address and its translation to the physical address. Additionally, if an instruction loop fits in four BTAC entries, instruction cache accesses are turned off to lower power consumption.

Note: Both GHB and BTAC RAMs implement parity for protection; however, this support has limited diagnostic value. Corruption in GHB data or BTAC data does not generate functional errors in the Cortex-A9 processor. Corruption in GHB data or BTAC data results in faulty branch prediction that is detected and corrected when the branch gets executed.

The Cortex-A9 CPU can predict conditional branches, unconditional branches, indirect branches, PC-destination data-processing operations, and branches that switch between Arm and Thumb states. However, the following branch instructions are not predicted:

  • Branches that switch between states (except Arm to Thumb transitions, and Thumb to Arm transitions)
  • Instructions with the S suffix are not predicted, as they are typically used to return from exceptions and have side effects that can change privilege mode and security state.
  • All mode-changing instructions

You can enable program flow prediction by setting the Z bit in the CP15 c1 Control register to 1 . Refer to the System Control Register in the Arm Cortex-A9 Technical Reference Manual (see Additional Resources and Legal Notices). Before switching the program flow prediction on, a BTAC flush operation must be performed which has the additional effect of setting the GHB into a known state.

Cortex-A9 also employs an 8-entry return stack cache that holds the 32-bit subroutine return addresses. This feature greatly reduces the penalty of executing subroutine calls and can address nested routines up to eight levels deep.