The following table lists all of the default terminations for each of the LVAUX I/O standards supported by the XQ ruggedized UltraScale+ devices when using the SSN predictor tool in the Vivado Design Suite.

Table 1. Default Termination for SSN Noise Analysis by I/O Standard
I/O Standard Drive Termination Option
DIFF_AIO12_LVAUX Far VCCO 40Ω
DIFF_SSTL12_LVAUX Far VTT 40Ω
LVCMOS12_LVAUX 8 None
LVDS12_LVAUX Far differential 100Ω
AIO12_LVAUX Far VCCO 40Ω
SSTL12_LVAUX Far VTT 40Ω