Methodology - UG584

Using LVAUX Mode in XQ Ruggedized UltraScale+ Devices for Airborne Systems Design Guide (UG584)

Document ID
UG584
Release Date
2024-05-03
Revision
1.1 English
  1. Fill in XPE as if you are designing in standard operating mode: Using the Xilinx Power Estimator User Guide (UG440), configure XPE. You should populate as many of the settings and sheets as possible to get an accurate estimate.
    Important: You cannot change the VCCAUX_IO power supply to 1.2V in the summary sheet. Leave the cell as 1.8V.

    When populating the I/O sheet, you cannot select the LVAUX I/O standards. Instead, use the counterpart to the LVAUX I/O standard you intended to use as shown in Table 1.

  2. Estimate the power consumption of HP I/O (only): Configure XPE with values for HP I/O banks only.
    • Keep the number of HP I/O input pins, output pins, and bidirectional pins to their current values.
    • Set the number of HD I/O input pins, output pins, and bidirectional pins to zero.
    • Record the total power drawn for VCCAUX_IO. This is the total static and dynamic power drawn from the HP I/O banks.
    • Divide this number by the voltage of the VCCAUX_HPIO power supply (nominally 1.2V) to get the current (A) estimate for the HP I/O banks.
  3. Estimate the power consumption of HD I/O (only): Configure XPE with values for HD I/O banks only.
    • Set the number of HD I/O input pins, output pins, and bidirectional pins back to their correct values.
    • Set the number of HP I/O input pins, output pins, and bidirectional pins to zero
    • Record the total power drawn for VCCAUX_IO. This is the total static and dynamic power drawn from the HD I/O banks.
    • Divide this number by the voltage of the VCCAUX_HDIO power supply (nominally 1.8V) to get the current (A) estimate for the HD I/O banks.