Designing with the MicroBlaze V Processor - 2024.1 English

MicroBlaze V Processor Embedded Design User Guide (UG1711)

Document ID
UG1711
Release Date
2024-08-01
Version
2024.1 English
  1. In the Flow Navigator panel, under IP Integrator, click the Create Block Design button to open the Create Block Design dialog box.
  2. Type the Design Name, as shown in the following figure.

    The Block Design window opens, as shown in the following figure.



  3. Within the empty design, click Add IP button on the design canvas. Alternatively, right-click in the canvas and select Add IP.

    A Search box lets you search and select the MicroBlaze V processor as shown in the following figure.



    When you double-click the MicroBlaze V IP, the Vivado IP integrator adds the IP to the design, and a graphical representation of the processing system displays, as shown in the following figure.



    Note: The Tcl command is as follows:
    create_bd_cell -type ip -vlnv xilinx.com:ip:microblaze_riscv:1.0 microblaze_riscv_0
  4. Double-click the MicroBlaze V IP in the canvas to invoke the Re-customize IP process, which displays the Re-customize IP dialog box for the MicroBlaze V processor, shown in the Using the MicroBlaze V Configuration Wizard.