Write_Completion_Ctrl (OSPI_QSPI) Register Description
| Register Name | Write_Completion_Ctrl |
|---|---|
| Offset Address | 0x0000000038 |
| Absolute Address | 0x0004090038 () |
| Width | 32 |
| Type | mixedMixed types. See bit-field details. |
| Reset Value | 0x00010005 |
| Description | Write Completion Control |
This register defines how the controller will poll the device following a write transfer Alternate register name: write_completion_ctrl_reg
Write_Completion_Ctrl (OSPI_QSPI) Register Bit-Field Summary
| Field Name | Bits | Type | Reset Value | Description |
|---|---|---|---|---|
| poll_rep_delay | 31:24 | rwNormal read/write | 0x0 | Defines additional delay for maintain Chip Select de-asserted during auto-polling phase Note: Field name reference: poll_rep_delay_fld |
| poll_count | 23:16 | rwNormal read/write | 0x1 | Defines the number of times the controller should expect to see a true result from the polling in successive reads of the device register. Minimum recommended value for this field is 3. Note: Field name reference: poll_count_fld |
| enable_polling_exp | 15 | rwNormal read/write | 0x0 | Set to 1 for enabling auto-polling expiration. Note: Field name reference: enable_polling_exp_fld |
| disable_polling | 14 | rwNormal read/write | 0x0 | This switches off the automatic polling function Note: Field name reference: disable_polling_fld |
| polling_polarity | 13 | rwNormal read/write | 0x0 | Defines the polling polarity. If 1, then the write transfer to the device will be complete if the polled bit is equal to 1. If 0, then the write transfer to the device will be complete if the polled bit is equal to 0. Note: Field name reference: polling_polarity_fld |
| Reserved | 12 | roRead-only | 0x0 | Reserved Note: Field name reference: wr_comp_ctrl_resv1_fld |
| polling_addr_en | 11 | rwNormal read/write | 0x0 | Enables address phase of auto-polling (Read Status) command. Note: Field name reference: polling_addr_en_fld |
| polling_bit_index | 10:8 | rwNormal read/write | 0x0 | Defines the bit index that should be polled. A value of 010 means that bit 2 of the returned data will be polled for.A value of 111 means that bit 7 of the returned data will be polled for. Note: Field name reference: polling_bit_index_fld |
| opcode | 7:0 | rwNormal read/write | 0x5 | Defines the opcode that should be issued by the controller when it is automatically polling for device program completion. This command is issued followed all device write operations. By default, this will poll the standard device STATUS register using opcode 0x05 Note: Field name reference: opcode_fld |