| Field Name | Bits | Type | Reset Value | Description |
| RSVD_READS_0 | 31:15 | roRead-only | 0x0 | This bit is reserved and reads 0 |
| INIT_COMPLETE | 14 | roRead-only | 0x0 | Device initialization complete |
| DCI_LOCK | 13 | roRead-only | 0x0 | IO DCI lock status |
| PLL_LOCK | 12 | roRead-only | 0x0 | PLL/DDRMC lock status |
| EOS | 11 | roRead-only | 0x0 | End of Startup |
| GWE | 10 | roRead-only | 0x0 | Global Write Enable |
| GTS_CFG | 9 | roRead-only | 0x0 | Global Tri-State |
| GHIGH | 8 | roRead-only | 0x0 | Global GHIGH |
| Reserved | 7:5 | roRead-only | 0x0 | Reserved Note: Field name reference: PLL_STARTUP_STATE |
| PUDC_B | 4 | roRead-only | 0x0 | Reads out the PUDC_B pin value |
| Reserved | 3 | roRead-only | 0x0 | Reserved |
| DONE | 2 | roRead-only | 0x0 | Indicates whether the configuration is complete, identical to done pin |
| JRDBK_ERROR | 1 | roRead-only | 0x0 | Error detected indication during the JRDBK instruction. A value of 1 means that TAP controller didn't find any data from SBI while trying to shift the config data out during JRDBK instruction. |
| JCONFIG_ERROR | 0 | roRead-only | 0x0 | Error detected during the JCONFIG instruction. A value of 1 means that SBI is not ready to accept the data from TAP |