IRQ_STATUS (SBI) Register - IRQ_STATUS (SBI) Register - UG1679

Kintex UltraScale+ Gen 2 and Spartan UltraScale+ FPGA Register Reference (UG1679)

Document_ID
UG1679
Release_Date
2026-08-12
Revision
1.2

IRQ_STATUS (SBI) Register Description

Register NameIRQ_STATUS
Offset Address0x0000000300
Absolute Address 0x0004110300 ()
Width32
TypemixedMixed types. See bit-field details.
Reset Value0x00000000
DescriptionSBI Interrupt Status Register. This is a sticky register that holds the value of the interrupt. Writing a 1 will clear the status.

IRQ_STATUS (SBI) Register Bit-Field Summary

Field NameBitsTypeReset ValueDescription
Reserved31:12razRead as zero0x0Reserved
MCAP_RESET_SEEN11wtcReadable, write a 1 to clear0x01:
When mcap_reset is set, write 1 to clear this bit when mcap_reset service is
complete.
MCAP_MODE_FE10wtcReadable, write a 1 to clear0x0When this bit is 1 falling
edge mcap_mode is
detected - plm should release mcap_mode configuration in SBI_CTRL.Interface.
MCAP_MODE_RE 9wtcReadable, write a 1 to clear0x0When this bit is 1
rising edge mcap_mode is
detected - plm should set mcap_mode configuration in SBI_CTRL.Interface.
JTAG_OVF_ERR 8wtcReadable, write a 1 to clear0x0JTAG overflow error encountered. If CDC FIFO is full and JTAG data is valid, the JTAG overflow error is reported by jtag_ovf_err.
SMAP_OVF_ERR 7wtcReadable, write a 1 to clear0x0SMAP overflow error encountered. If CDC FIFO is full and there is write to SMAP interface, the SMAP overflow error is reported by smap_ovf_err.
SS_OVF_ERR 6wtcReadable, write a 1 to clear0x0Slave serial overflow error encountered. If CDC FIFO is full and there is write to slave serial interface, slave serial overflow error is reported by ss_ovf_err.
MCAP_OVF_ERR 5wtcReadable, write a 1 to clear0x0MCAP overflow error encountered. If CDC FIFO is full and mcap_cs_b = 0 and mcap_rdwr_b = 0, MCAP overflow error is reported by mcap_ovf_err.
AXI_APB_ERR 3wtcReadable, write a 1 to clear0x0PMC Main Switch AXI slave error. Asserts when awsize is not 4 bytes or burst type is WRAP during an AXI transaction.
DATA_RDY 2wtcReadable, write a 1 to clear0x0Valid configuration data into SBI buffer which will raise an interrupt to the Micro Blaze.
SMAP_ABORT 1wtcReadable, write a 1 to clear0x0A SelectMAP abort is triggered when RDWR_B toggles while CSI_B is asserted. This can happen during SelectMap configuration or readback sequence. (Requires SBI block reset and CCLK running to clear this status)
INV_APB 0wtcReadable, write a 1 to clear0x0APB (register) access occurs to an unimplemented space, slave error.