| Field Name | Bits | Type | Reset Value | Description |
| Reserved | 31:8 | razRead as zero | 0x0 | Reserved |
| tamper_fabric | 7 | roRead-only | 0x1 | IMR for fabric temper detection |
| sysmon_ot | 6 | roRead-only | 0x1 | IMR for Sysmon Over-Temperature |
| bad_pr_format | 5 | roRead-only | 0x1 | IMR for bad per frame CRC partial bitstream format error |
| seu_ecc_error | 4 | roRead-only | 0x1 | IMR for SEU readback ECC error |
| seu_crc_error | 3 | roRead-only | 0x1 | IMR for SEU readback CRC error |
| crc_error | 2 | roRead-only | 0x1 | IMR for bitstream crc32 error |
| idcode_error | 1 | roRead-only | 0x1 | IMR for bitstream IDCODE error |
| apb_error | 0 | roRead-only | 0x1 | IMR for APB slave error |