Inserting the Adapter in a PCI Express Slot - Inserting the Adapter in a PCI Express Slot - UG1659

AMD Solarflare SFN8041 Network Adapter Quick Start Guide (UG1659)

Document ID
UG1659
Release Date
2024-12-19
Revision
1.0 English

The SFN8041 QSFP+ single-port adapter is a half-height, half-length, 8-lane PCIe 3.1 form factor adapter.

Note: The AMD Solarflare SFN8041 server adapter requires an 8-lane or 16-lane PCI Express slot. For maximum performance the adapter should be installed in a PCIe 3.1 or PCIe 3.0 slot, but is compatible with PCIe 2.0 or PCIe 1.x.

Shut down the server and unplug it from its power source. Remove the server cover to access the PCI Express slots in the server. Locate an 8-lane or 16-lane PCI Express slot (refer to the server manual if necessary) and insert the AMD Solarflare server adapter. Secure the adapter bracket in the slot.

Figure 1. Inserting the Adapter in a PCI Express Slot
CAUTION: