The following table lists the default switch settings.
Callout Number | Ref. Des. | Function | Default | Schematic Page |
---|---|---|---|---|
14 | SW1 | U1 mode 4-pole DIP switch Switch OFF = 1 = high; ON = 0 = low Mode = SW1[1:4] = Mode[0:3] SD = ON,OFF,OFF,OFF = 0111 OSPI = ON,ON,ON,OFF = 0001 JTAG = ON,ON,ON,ON = 0000 |
ON, ON, ON, ON | 12 |
15 | SW2 | VEK280 power-on reset (POR_B) | Open | 13 |
16 | SW3 | SYSCTLR JTAG source selection Switch OFF = 1 = high; ON = 0 = low SYSCTLR JTAG SOURCE SEL = SW3[1:2] = SEL[0:1] PL JTAG = ON,ON = 00 FTDI JTAG = OFF,ON = 10 |
OFF, ON | 20 |
17 | SW4, SW5 | User pushbutton inputs Note: Pushbutton switch default = open = logic low (not
pressed).
|
Open | 48 |
18 | SW6 | User GPIO DIP Switch OFF = 0 = low; ON = 1 = high |
OFF, OFF, OFF, OFF | 48 |
19 | SW12 | System controller power-on reset (SYSCTL_POR_B) | Open | 77 |
20 | SW13 | Main power | OFF | 50 |
21 | SW14 | User USB reset | Open | 37 |
22 | SW15 | User GEM reset | Open | 36 |
23 | SW16 | System controller FWUEN pushbutton (SYSCTLR_MIO12_FWUEN_C2M_B) See BEAM wiki for more information |
Open | 76 |