Switches

VEK280 Evaluation Board User Guide (UG1612)

Document ID
UG1612
Release Date
2024-01-31
Revision
1.1 English

The following table lists the default switch settings.

Table 1. Default Switch Settings
Callout Number Ref. Des. Function Default Schematic Page
14 SW1 U1 mode 4-pole DIP switch

Switch OFF = 1 = high; ON = 0 = low

Mode = SW1[1:4] = Mode[0:3]

SD = ON,OFF,OFF,OFF = 0111

OSPI = ON,ON,ON,OFF = 0001

JTAG = ON,ON,ON,ON = 0000

ON, ON, ON, ON 12
15 SW2 VEK280 power-on reset (POR_B) Open 13
16 SW3 SYSCTLR JTAG source selection

Switch OFF = 1 = high; ON = 0 = low

SYSCTLR JTAG SOURCE SEL = SW3[1:2] = SEL[0:1]

PL JTAG = ON,ON = 00

FTDI JTAG = OFF,ON = 10

OFF, ON 20
17 SW4, SW5 User pushbutton inputs
Note: Pushbutton switch default = open = logic low (not pressed).
Open 48
18 SW6 User GPIO DIP

Switch OFF = 0 = low; ON = 1 = high

OFF, OFF, OFF, OFF 48
19 SW12 System controller power-on reset (SYSCTL_POR_B) Open 77
20 SW13 Main power OFF 50
21 SW14 User USB reset Open 37
22 SW15 User GEM reset Open 36
23 SW16 System controller FWUEN pushbutton (SYSCTLR_MIO12_FWUEN_C2M_B)

See BEAM wiki for more information