Switches

VPK180 Evaluation Board User Guide (UG1582)

Document ID
UG1582
Release Date
2023-05-10
Revision
1.1 English

The following table lists the default switch settings.

Table 1. Default Switch Settings
Callout Number Ref. Des. Function Default Schematic Page
11 SW1 U1 mode 4-pole DIP switch

Switch OFF = 1 = high; ON = 0 = low

Mode = SW1[1:4] = Mode[0:3]

SD = ON,OFF,OFF,OFF = 0111

QSPI32 = ON,OFF,ON,ON = 0100

JTAG = ON,ON,ON,ON = 0000

ON, ON, ON, ON 22
12 SW2 VPK180 power-on reset (POR_B) Open 23
13 SW3 SYSCTLR JTAG source selection

Switch OFF = 1 = high; ON = 0 = low

SYSCTLR JTAG SOURCE SEL = SW3[1:2] = SEL[0:1]

PL JTAG = ON,ON = 00

FTDI JTAG = OFF,ON = 10

Trace Mictor38 JTAG = ON,OFF = 01

OFF, ON 35
14 SW4, SW5 User pushbutton inputs
Note: Pushbutton switch default = open = logic low (not pressed).
Open 65
15 SW6 User GPIO DIP

Switch OFF = 0 = low; ON = 1 = high

OFF, OFF, OFF, OFF 65
16 SW11 SYSCTLR mode 4-pole DIP switch

Switch OFF = 1 = high; ON = 0 = low

Mode = SW1[1:4] = Mode[0:3]

QSPI32 = ON,OFF,ON,ON = 0100

eMMC = ON,OFF,OFF,ON = 0110

JTAG = ON,ON,ON,ON = 0000

ON, OFF, ON, ON 97
17 SW12 System controller power-on reset (SYSCTL_POR_B) Open 97
18 SW13 Main power OFF 66
19 SW14 User USB reset Open 53
20 SW15 User GEM reset Open 52
21 SW16 System controller FWUEN pushbutton (SYSCTLR_MIO12_FWUEN_C2M_B)

See BEAM wiki for more information

Open 96