The QSFP-DD control signals can be asserted in multiple ways. Each QSFP-DD has an I2C connection to the I2C1 bus through the I2C multiplexer (TCA9548PWR U35) as shown in the PMC MIO[44:45] I2C1 Bus section.
The following table lists the transceiver module control signals.
Signal Name | Feature | Notes | Schematic Page |
---|---|---|---|
QSFPDD_I2C_SDA | Two-wire interface data | U35 I2C MUX | 56-59 |
QSFPDD_I2C_SCL | Two-wire interface clock | U35 I2C MUX | 56-59 |
QSFPDD1_MODSELL | Module select | U233 P00 | 6, 55, 57 |
QSFPDD1_RESETL | Module reset | U1 Bank 711 | 6, 57 |
QSFPDD1_MODPRSL | Module present | U1 Bank 711 | 6, 57 |
QSFPDD1_INTL | Interrupt | U1 Bank 711 | 6, 57 |
QSFPDD1_INITMODE | Low power mode | U1 Bank 711 | 6, 57 |
QSFPDD2_MODSELL | Module select | U233 P01 | 6, 55, 57 |
QSFPDD2_RESETL | Module reset | U1 Bank 711 | 6, 57 |
QSFPDD2_MODPRSL | Module present | U1 Bank 711 | 6, 57 |
QSFPDD2_INTL | Interrupt | U1 Bank 711 | 6, 57 |
QSFPDD2_INITMODE | Low power mode | U1 Bank 711 | 6, 57 |
QSFPDD3_MODSELL | Module select | U233 P02 | 6, 55, 58 |
QSFPDD3_RESETL | Module reset | U1 Bank 711 | 6, 58 |
QSFPDD3_MODPRSL | Module present | U1 Bank 711 | 6, 58 |
QSFPDD3_INTL | Interrupt | U1 Bank 711 | 6, 58 |
QSFPDD3_INITMODE | Low power mode | U1 Bank 711 | 6, 58 |
QSFPDD4_MODSELL | Module select | U233 P03 | 6, 55, 58 |
QSFPDD4_RESETL | Module reset | U1 Bank 711 | 6, 58 |
QSFPDD4_MODPRSL | Module present | U1 Bank 711 | 6, 58 |
QSFPDD4_INTL | Interrupt | U1 Bank 711 | 6, 58 |
QSFPDD4_INITMODE | Low power mode | U1 Bank 711 | 6, 58 |
QSFPDD5_MODSELL | Module select | U233 P05 | 6, 55, 59 |
QSFPDD5_RESETL | Module reset | U1 Bank 711 | 6, 59 |
QSFPDD5_MODPRSL | Module present | U1 Bank 711 | 6, 59 |
QSFPDD5_INTL | Interrupt | U1 Bank 711 | 6, 59 |
QSFPDD5_INITMODE | Low power mode | U1 Bank 711 | 6, 59 |
QSFPDD6_MODSELL | Module select | U233 P06 | 6, 55, 59 |
QSFPDD6_RESETL | Module reset | U1 Bank 711 | 6, 59 |
QSFPDD6_MODPRSL | Module present | U1 Bank 711 | 6, 59 |
QSFPDD6_INTL | Interrupt | U1 Bank 711 | 6, 59 |
QSFPDD6_INITMODE | Low power mode | U1 Bank 711 | 6, 59 |
OSFP_I2C_SDA | Two-wire interface data | U35 I2C MUX | 56, 60 |
OSFP_I2C_SCL | Two-wire interface clock | U35 I2C MUX | 56, 60 |
OSFP_H_LPWN_N | U1 to module low power mode | U2 level shift | 7, 57, 60 |
OSFP_H_PRS_N | Module to U1 module present | U9 level shift | 7, 57, 60 |
OSFP_H_INTN | Module to U1 interrupt | U9 level shift | 7, 57, 60 |
OSFP_H_RSTN | U1 to module reset | U2 level shift | 7, 57, 60 |
SFPDD1_I2C_SDA | Two-wire interface data | U322 I2C MUX | 56, 63 |
SFPDD1_I2C_SCL | Two-wire interface clock | U322 I2C MUX | 56, 63 |
SFPDD1_CH0_TXFAULT | Module to U1 - fault condition detected | U1 Bank 709 | 6, 63 |
SFPDD1_CH0_TXDISABLE | U1 to module - transmitter disable | U1 Bank 709 | 6, 63 |
SFPDD1_CH0_SPEED1 | Module receive rate selection | Float on board | 63 |
SFPDD1_CH0_SPEED2 | Module receive rate selection | Float on board | 63 |
SFPDD1_CH0_RXLOS | Module to U1 - RX signal loss | U1 Bank 709 | 6, 63 |
SFPDD1_CH1_TXFAULTDD | U1 to module - transmitter disable | U1 Bank 709 | 6, 63 |
SFPDD1_CH1_TXDISABLEDD | Module to U1 - fault condition interrupt/detected | U1 Bank 709 | 6, 63 |
SFPDD1_CH1_SPEED1DD | Module receive - rate selection | Float on board | 63 |
SFPDD1_CH1_SPEED2DD | Module receive - rate selection | Float on board | 63 |
SFPDD1_CH1_RXLOSDD | Module to U1 - RX signal loss | U1 Bank 709 | 6, 63 |
SFPDD1_MOD_ABS | Module to U1 - module absent | U1 Bank 709 | 6, 63 |
SFPDD1_LPMODE | U1 to module - low power mode | Float on board | 63 |
SFPDD1_RESETL | U1 to module - complete module reset | U1 Bank 709 | 6, 63 |
SFPDD2_I2C_SDA | Two-wire interface data | U322 I2C MUX | 56, 63 |
SFPDD2_I2C_SCL | Two-wire interface clock | U322 I2C MUX | 56, 63 |
SFPDD2_CH0_TXFAULT | Module to U1 - fault condition detected | U1 Bank 709 | 6, 63 |
SFPDD2_CH0_TXDISABLE | U1 to module - transmitter disable | U1 Bank 709 | 6, 63 |
SFPDD2_CH0_SPEED1 | Module receive rate selection | Float on board | 63 |
SFPDD2_CH0_SPEED2 | Module receive rate selection | Float on board | 63 |
SFPDD2_CH0_RXLOS | Module to U1 - RX signal loss | U1 Bank 709 | 6, 63 |
SFPDD2_CH1_TXFAULTDD | U1 to module - transmitter disable | U1 Bank 709 | 6, 63 |
SFPDD2_CH1_TXDISABLEDD | Module to U1 - fault condition interrupt/detected | U1 Bank 709 | 6, 63 |
SFPDD2_CH1_SPEED1DD | Module receive - rate selection | Float on board | 63 |
SFPDD2_CH1_SPEED2DD | Module receive - rate selection | Float on board | 63 |
SFPDD2_CH1_RXLOSDD | Module to U1 - RX signal loss | U1 Bank 709 | 6, 63 |
SFPDD2_MOD_ABS | Module to U1 - module absent | U1 Bank 709 | 6, 63 |
SFPDD2_LPMODE | U1 to module - low power mode | Float on board | 63 |
SFPDD2_RESETL | U1 to module - complete module reset | U1 Bank 709 | 6, 63 |
SFPDD3_I2C_SDA | Two-wire interface data | U322 I2C MUX | 56, 64 |
SFPDD3_I2C_SCL | Two-wire interface clock | U322 I2C MUX | 56, 64 |
SFPDD3_CH0_TXFAULT | Module to U1 - fault condition detected | U1 Bank 710 | 6, 64 |
SFPDD3_CH0_TXDISABLE | U1 to module - transmitter disable | U1 Bank 710 | 6, 64 |
SFPDD3_CH0_SPEED1 | Module receive - rate selection | Float on board | 64 |
SFPDD3_CH0_SPEED2 | Module receive - rate selection | Float on board | 64 |
SFPDD3_CH0_RXLOS | Module to U1 - RX signal loss | U1 Bank 710 | 6, 64 |
SFPDD3_CH1_TXFAULTDD | U1 to module - transmitter disable | U1 Bank 710 | 6, 64 |
SFPDD3_CH1_TXDISABLEDD | Module to U1 - fault condition interrupt/detected | U1 Bank 710 | 6, 64 |
SFPDD3_CH1_SPEED1DD | Module receive - rate selection | Float on board | 64 |
SFPDD3_CH1_SPEED2DD | Module receive - rate selection | Float on board | 64 |
SFPDD3_CH1_RXLOSDD | Module to U1 - RX signal loss | U1 Bank 710 | 6, 64 |
SFPDD3_MOD_ABS | Module to U1 - module absent | U1 Bank 710 | 6, 64 |
SFPDD3_LPMODE | U1 to module - low power mode | Float on board | 64 |
SFPDD3_RESETL | U1 to module - complete module reset | U1 Bank 710 | 6, 64 |
SFPDD4_I2C_SDA | Two-wire interface data | U322 I2C MUX | 56, 64 |
SFPDD4_I2C_SCL | Two-wire interface clock | U322 I2C MUX | 56, 64 |
SFPDD4_CH0_TXFAULT | Module to U1 - fault condition detected | U1 Bank 710 | 6, 64 |
SFPDD4_CH0_TXDISABLE | U1 to module - transmitter disable | U1 Bank 710 | 6, 64 |
SFPDD4_CH0_SPEED1 | Module receive rate selection | Float on board | 64 |
SFPDD4_CH0_SPEED2 | Module receive rate selection | Float on board | 64 |
SFPDD4_CH0_RXLOS | Module to U1 - RX signal loss | U1 Bank 710 | 6, 64 |
SFPDD4_CH1_TXFAULTDD | U1 to module - transmitter disable | U1 Bank 710 | 6, 64 |
SFPDD4_CH1_TXDISABLEDD | Module to U1 - fault condition interrupt/detected | U1 Bank 710 | 6, 64 |
SFPDD4_CH1_SPEED1DD | Module receive - rate selection | Float on board | 64 |
SFPDD4_CH1_SPEED2DD | Module receive - rate selection | Float on board | 64 |
SFPDD4_CH1_RXLOSDD | Module to U1 - RX signal loss | U1 Bank 710 | 6, 64 |
SFPDD4_MOD_ABS | Module to U1 - module absent | U1 Bank 710 | 6, 64 |
SFPDD4_LPMODE | U1 to module - low power mode | Float on board | 64 |
SFPDD4_RESETL | U1 to module - complete module reset | U1 Bank 710 | 6, 64 |