The following table lists the default jumper settings.
Callout Number | Ref. Des. | Function | Default | Schematic Page |
---|---|---|---|---|
1 | J12 | SYSMON header (see schematic) | Open | 20 |
2 | J26 | POR_B supervisor SENSE input 1-2: VCCO_MIO ramp-up sense (1.8V) 2-3: VCCAUX_PMC ramp-up sense (1.5V) |
1-2 | 23 |
3 | J326 | POR_B enable header 1-2: SYSCTLR can drive POR_B 3-4: PC4 can drive POR_B 5-6: FTDI can drive POR_B Open: POR_B source not connected |
1-2, 3-4 jumpered 5-6 open |
23 |
4 | J34 | VCC Fuse programming enable 1-2: Fuse programming enabled 2-3: Fuse programming disabled |
2-3 | 25 |
4 | J37 | JTAG source enable 1-2: JTAG sources disabled 2-3: JTAG sources enabled |
2-3 | 35 |
5 | J300 | USB shield GND 1-2: USB connector DC grounded 2-3: USB connector no DC grounded |
1-2 | 53 |
6 | J301 | SD REF 1-2: 3.3V REF 2-3: GND REF |
1-2 | 51 |
7 | J203 | SYSCTLR POR_B supervisor enable 1-2: SYSCTLR POR_B supervisor enabled Open: SYSCTLR POR_B supervisor disabled |
1-2 | 97 |
8 | J347 | Fan type 1-2: System controller PWM 2-3: Versal device MIO PWM |
1-2 | 66 |
8 | J348 | TACH type 1-2: System controller TACH 2-3: Versal device MIO TACH |
1-2 | 66 |
9 | J345 | LPDMGTYAVTT enable select Installed: Versal device control Not installed: enabled by UTIL_5V0_PGOOD |
Open | 90 |
10 | J12 | SYSMON VREF selection Default VREF = 1.024V |
1-2 | 20 |