This section outlines the steps to generate and program the MCS file.
MCS File Generation
The MCS file represents the PROM image which is loaded onto the Alveo U55C data center accelerator card at power ON. It is generated using the write_cfgmem tool. This section outlines the steps to generate and program the MCS file.
Prior to generating the MCS file, ensure your project XDC file sets the following properties.
- CONFIG_VOLTAGE
- BITSTREAM.CONFIG.CONFIGFALLBACK
- BITSTREAM.GENERAL.COMPRESS
- CONFIG_MODE
- BITSTREAM.CONFIG.SPI_BUSWIDTH
- BITSTREAM.CONFIG.CONFIGRATE
- BITSTREAM.CONFIG.EXTMASTERCCLK_EN
- BITSTREAM.CONFIG.SPI_FALL_EDGE
- BITSTREAM.CONFIG.UNUSEDPIN
- BITSTREAM.CONFIG.SPI_32BIT_ADDR
Use the following command line with the parameters outlined in Table 1 to generate the MCS file.
write_cfgmem -force -format mcs -interface <interface_type> -size <size> -loadbit "up <user_config_region_offset> <input_file.bit>" -file "<output_file.mcs>"
| write_cfgmem Parameter | Setting |
|---|---|
| interface_type |
spix4
|
| user_config_region_offset 1 |
0x01002000
|
| size | 128 |
| input_file.bit | Filename of the input .bit file |
| output_file.mcs | MCS output filename |
|
|
For additional details on write_cfgmem, see the UltraScale Architecture Configuration User Guide (UG570).
Program the Alveo Card
After the MCS file has been generated, use the following steps to flash the Alveo U55C data center accelerator card using the Vivado hardware manager. Detailed steps for programming the FPGA are outlined in the chapter Programming the FPGA Device in the Vivado Design Suite User Guide: Programming and Debugging (UG908).
- Connect to the Alveo U55C data center accelerator card using the Vivado hardware manager via the maintenance connector or micro-USB port. Details on connecting to the Alveo card through the maintenance connector are provided in the Alveo Programming Cable User Guide (UG1377).
- Select Add Configuration Device and select the mt25qu01g-spi-x1_x2_x4 part.
- Right-click the target to select Program the Configuration Memory Device.
- Select the MCS file target.
- Select Configuration File Only.
- Click OK.
- After programming has completed, disconnect the card in the hardware manager, and disconnect the JTAG programming cable from the Alveo U55C data center accelerator card.
- Perform a cold reboot on the host machine to complete the card update.Important: When switching between an Alveo data center accelerator card target platform and a custom design, revert the card to the factory image before loading an alternate image into the PROM. See Xilinx Answer Record 71757 for more information.