You can create, edit, or remove cross-trigger breakpoints and apply the breakpoints on the target using the Launch Configurations page. To enable cross-triggering, do the following.

  1. Launch the Vitis unified IDE.
  2. Create a standalone application component and build it. Alternatively, you can select an existing application component.
  3. Go to the Flow Navigator and select the application component.
  4. See Launch Configurations and Creating a New Target Connection to launch the debug configuration and set the target connection.
  5. Enable Enable Cross Triggering check-box in the launch configuration page. The Cross Trigger Breakpoints interface is displayed.
  6. Click Add Item to create new breakpoints.

    You can set the input and output signals or set the mode of skip on step on this screen.