The following steps illustrate user managed flow design debug for hardware debug.
  1. Burn sd_card.img to a physical SD card. This creates a boot-able medium for your target platform.
  2. Insert the SD card into the card reader of the VCK190 evaluation kit.
  3. Change the boot-mode settings of the card to SD boot mode, and power up the board.
  4. After the VCK190 is booted, enter the mount command at the command prompt to get a list of mount points. As shown in the following figure, the mount command displays mounting information for the system.
    Note: Be sure to capture the proper path for the cd command in the next step, and subsequent commands, based on the results of the mount command.


  5. Execute the following commands: cd /run/media/mmcblk0p1
  6. Run ifconfig to retrieve the IP address of the target card. The IP address is used to set up a TCF agent connection in the Vitis Unified IDE. The target needs to connect to the network assigned IP address.

  7. Within the Vitis Unified IDE, select or create a target connection to the remote accelerator card as follows:
    1. Select the Vitis → Target Connections command from the main menu to open the Target Connections dialog box.
    2. Select an existing Linux TCF Agent connection, or right-click Linux TCF Agent and select the New Target command to open the New Target Connection dialog box as shown in the following figure.