The NoC XPMs contain the following parameters:
- NOC_FABRIC
- Choosing the required NMU/NSU of the given device, available values are VNoC and BLI, default is VNoC. VNoC NoC instances are distributed throughout the NoC fabric. Boundary Logic Interface (BLI) registers are usually confined to the perimeter of the PL fabric.
- DATA_WIDTH
- AXI Channel Data width, allowed values are 32, 64, 128, 256, and 512. The default value is 512.
- ADDR_WIDTH
- AXI Channel Address Width, allowed values are from 12 to 64. The default value is 64.
- ID_WIDTH
- AXI Channel ID PORT width, allowed values are 1 to 16. The default value is 16.
- AUSER_WIDTH
- Allowed values are 16 and 18, which disables/enables parity, respectively. The default value is 16.
- DST_ID_WIDTH
- AXI Channel DST post width. Available only for streaming interfaces. Allowed values are 1 to 4. The default value is 4.
- DUSER_WIDTH
- User defined width for USER bits.
- ENABLE_USR_INTERRUPT
- Signal to enable/disable 4-bit interrupt.
- SIDEBAND_PINS
- Parameter to enable/disable AXI sideband pins. Sideband pins are low-order bits added to the AXI USER field, without affecting the contents of the USER field, that are typically used to pass parity or SMID information through the AXI network.