Temperature Humidity with Bias Test

Device Reliability Report (UG116)

Document ID
UG116
Release Date
2024-11-08
Revision
10.19 English

The THB test is conducted under the conditions of 85°C and 85% RH and VDD bias. Package preconditioning is performed on the testing samples prior to the THB test.

The failures listed in the following table are also listed by device with failure analysis results in the footnotes.

Summary

Table 1. Summary of Temperature Humidity with Bias Test Results
Device Lot Quantity Fail Quantity Device Quantity Total Device Hours
XC3Sxxx 2 0 90 135,000
XC3SxxxE 8 0 354 575,000
XC5VxXxxx 3 0 139 186,000
XC6VxXxxx 3 0 134 201,000
UltraScale devices 7 0 307 447,000
UltraScale+ devices 9 0 401 691,000
Versal devices 8 0 260 349,500

Data

Table 2. THB Test Results for XC3Sxxx
Device Lot Quantity Fail Quantity Device Quantity Total Device Hours
XC3S400 2 0 90 135,000
XC3Sxxx 2 0 90 135,000
Table 3. THB Test Results for XC3SxxxE
Device Lot Quantity Fail Quantity Device Quantity Total Device Hours
XC3S100E 1 0 45 67,500
XC3S1200E 2 0 88 176,000
XC3S250E 2 0 86 129,000
XC3S500E 3 0 135 202,500
XC3SxxxE 8 0 354 575,000
Table 4. THB Test Results for XC5VxXxxx
Device Lot Quantity Fail Quantity Device Quantity Total Device Hours
XC5VLX110T 3 0 139 186,000
XC5VxXxxx 3 0 139 186,000
Table 5. THB Test Results for XC6VxXxxx
Device Lot Quantity Fail Quantity Device Quantity Total Device Hours
XC6VLX240T 3 0 134 201,000
XC6VxXxxx 3 0 134 201,000
Table 6. THB Test Results for UltraScale devices
Device Lot Quantity Fail Quantity Device Quantity Total Device Hours
XCKU040 3 0 127 190,500
XCKU060 1 0 45 54,000
XCKU115 3 0 135 202,500
UltraScale devices 7 0 307 447,000
Table 7. THB Test Results for UltraScale+ devices
Device Lot Quantity Fail Quantity Device Quantity Total Device Hours
XCZU15EG 1 0 45 67,500
XCZU3EG 3 0 135 270,000
XCZU7EV 1 0 44 88,000
XCZU9EG 4 0 177 265,500
UltraScale+ devices 9 0 401 691,000
Table 8. THB Test Results for Versal devices
Device Lot Quantity Fail Quantity Device Quantity Total Device Hours
XCVC1902 4 0 179 268,500
XCVP1802 4 0 81 81,000
Versal devices 8 0 260 349,500