Moisture sensitivity and reflow temperature information can be found in Device Package User Guide (UG112).
The non-hermetic package/assembly qualification is outlined in the following table. However, for hermetic package qualification, a full group B and D test per MIL-STD-883, Test Methods, is required.
Reliability Test | Conditions | Duration | Lot Quantity | Sample Size per Lot | Acceptance Criteria |
---|---|---|---|---|---|
THB 1 or HAST 1 | 85°C, 85% RH, VDD | 1,000 hours | 3 | 25 | 0 failures |
130°C, 85% RH, VDD | 96 hours | ||||
110°C, 85% RH, VDD | 264 hours | ||||
Temperature cycling 1, 2, 3, 4 | –65°C to +150°C | 500 cycles | 3 | 25 | 0 failures |
–55°C to +125°C | 1,000 cycles | ||||
–40°C to +125°C | 1,000 cycles | ||||
Autoclave 1 or temperature humidity unbiased 1 or UHAST 1 | 121°C, 100% RH | 96 hours | 3 | 25 | 0 failures |
85°C, 85% RH | 1,000 hours | ||||
130°C, 85% RH or 110°C, 85% RH | 96 hours or 264 hours | ||||
High-Temperature Storage (HTS) | TA=150°C | 1,000 hours | 3 | 25 | 0 failures |
|
The qualification process for new devices is shown in the following table.
Reliability Test | Conditions | Lot Quantity | Sample Size per Lot | Target Criteria |
---|---|---|---|---|
ESD | HBM 1 | 1 | 3 | 1,000V |
ESD | CDM 2 | 1 | 3 | 250V 3 |
Latch-up | Current injection | 1 | 3 | ±100 mA |
|