Inferring Differential Clock Interfaces - 2024.1 English

Vivado Design Suite User Guide: Creating and Packaging Custom IP (UG1118)

Document ID
UG1118
Release Date
2024-06-19
Version
2024.1 English

To properly infer a differential clock interface, each pin of the differential pair requires the same nomenclature, as shown in the following list.

  • [*_]clk_p
  • [*_]clk_n