Recommended BGA Ball Pad and Via Dimensions for 1.0 mm, 0.92 mm, 0.8 mm, and 0.5 mm Devices
The definition of dimensions of FPGA/adaptive SoC ball pads and vias for AMD BGA devices are show in the following figure. The table that follows shows the actual dimensions based on BGA ball pitch.
| Solder Ball Land Pitch (e) | 1.0 mm | 0.92 mm | 0.8 mm | 0.5 mm |
|---|---|---|---|---|
| Solder Mask Opening Diameter (L) | 20.9 mil | 20.9 mil | 15.7 mil | 11.0 mil |
| 0.53 mm | 0.53 mm | 0.40 mm | 0.28 mm | |
| BGA Solder Land Pad Diameter (M) | 19.7 mil | 20.0 mil |
15.7 mil |
10.2 mil |
| 0.50 mm | 0.51 mm | 0.40 mm | 0.26 mm | |
| Via Plating Diameter (VD) |
19 mil |
19 mil |
19 mil |
10 mil |
| 0.48 mm | 0.48 mm | 0.48 mm | 0.254 mm | |
| Via Finished Hole Diameter (VH) |
10 mil |
10 mil |
10 mil |
4 mil |
| 0.25 mm | 0.25 mm | 0.25 mm | 0.10 mm | |
| Distance between BGA Pad and Via) |
27.83 mil |
25.61 mil |
22.27 mil |
13.92 mil |
| 0.70 mm | 0.65 mm | 0.56 mm | 0.35 mm |
Recommended Trace Routing between Pads and Vias for 1.0 mm, 0.92 mm, 0.8 mm, and 0.5 mm Devices
The ball pitch and BGA pad/via diameters determine how much space is available to route traces between pads or vias. Standard PCB processes can allow for as low as 3.5 mil trace widths with 3.5 mil spacing. Advanced processes can allow for as low as 2 mil trace widths with 2 mil spacing. Recommended trace routing is shown in the following figure. The table that follows shows the actual BGA/trace routing dimensions.
| Solder Ball Land Pitch (e) | 39.39 mil | 36.22 mil | 31.40 mil | 19.7 mil |
|---|---|---|---|---|
| 1.0 mm | 0.92 mm | 0.8 mm | 0.5 mm | |
| PCB Solder Land Diameter (L) |
19.7 mil |
20.0 mil |
15.7 mil |
10.63 mil |
| 0.50 mm | 0.51 mm | 0.40 mm | 0.27 mm | |
| Available Routing Distance (R) | 19 mil | 16 mil | 15 mil | 9 mil |
| 0.33 mm | 0.40 mm | 0.38 mm | 0.23 mm | |
| Pad-to-Trace/Trace-to-Trace Spacing for one route between pads (S1) | 7.5 mil | 6 mil | 5 mil | 3 1 |
| 0.19 mm | 0.15 mm | 0.13 mm | 0.08 mm | |
| Trace thickness for one route between pads (W1) | 4 | 4 | 4 | 3 |
| 0.10 mm | 0.10 mm | 0.10 mm | 0.08 mm | |
| Pad-to-Trace/Trace-to-Trace Spacing for two route between pads (S2) |
4 mil |
3 mil |
3 mil | N/A |
| 0.10 mm | 0.08 mm | 0.08 mm | ||
| Trace thickness for two route between pads (W2) | 3 mil | 3 mil | 3 mil | N/A |
| 0.08 mm | 0.08 mm | 0.08 mm | ||
|
||||
Recommended Trace Routing between Vias
One or two traces can be routed in-between vias for 1.0 mm, 0.92 mm, and 0.80 mm pitch devices. It is not practical to route traces in-between vias spaced 0.5 mm apart due to the tight spacing and trace widths required. For those situations, it is recommended to use Via-in-Pad technology for added pitch between vias. Recommended via/trace routing is shown in the following figure. The table that follows shows the actual BGA/trace routing dimensions.
| Solder Ball Land Pitch (e) | 39.39 mil | 36.22 mil | 31.40 mil | 19.7 mil |
|---|---|---|---|---|
| 1.0 mm | 0.92 mm | 0.8 mm | 0.5 mm | |
| Via Drill Diameter (VD) | 10 mil | 10 mil | 10 mil | 4 mil |
| 0.25 mm | 0.25 mm | 0.25 mm | 0.10 mm | |
| Available Routing Distance (R) | 29 mil | 26 mil | 21 mil | 15 mil |
| 0.74 mm | 0.66 mm | 0.53 mm | 0.38 mm | |
| Via-to-Trace/Trace-to-Trace Spacing for one route between pads (S1) | 12 mil | 11 mil | 8 mil | 5 mil |
| 0.30 mm | 0.28 mm | 0.20 mm | 0.13 mm | |
| Trace thickness for one route between pads (W1) |
4 mil |
4 mil |
4 mil |
4 mil |
| 0.10 mm | 0.10 mm | 0.10 mm | 0.10 mm | |
| Pad-to-Trace/Trace-to-Trace Spacing for two route between pads (S2) | 10 mil | 6 mil | 5 mil | 3 mil 1 |
| 0.25 mm | 0.15 mm | 0.13 mm | 0.08 mm | |
| Trace thickness for two route between pads (W2) |
4 mil |
4 mil |
3 mil |
3 mil |
| 0.10 mm | 0.10 mm | 0.08 mm | 0.08 mm | |
|
||||