The total module power (TMP) represents the maximum board power dissipation while the system is running the target workload under worst-case conditions. System designs must be capable of providing enough cooling for the K24 SOM when operating at the TMP level. The TMP depends on how the SOM is configured and used. The TMP can be obtained via an accurate power estimation of the K24 SOM using the Power Design Manager (PDM) tool, detailed in the Power Estimation section. Prior to evaluating a thermal solution, the PDM tool provides the appropriate thermal loading based on your estimated inputs. The following figure maps the top-side view of the component placement on the K24 SOM PCB. The power dissipation values are listed in the following table.
The power presented in the following table is only an example. The actual power dissipation should be obtained from the PDM tool. For the purpose of a thermal simulation, some of the smaller components are removed.
| Type | Part Reference | Description | Maximum Thermal Specifications | Metal Enclosure TC Monitor | |
|---|---|---|---|---|---|
| Tj (°C) | TC (°C) | ||||
| MPSoC | U1 | XCK24-UBVA530-2LV | 85 (C) 100 (I) |
N/A | Yes |
| Memory | U173, U175 | LPDDR4 memory | N/A | 85 (C) 105 (I) |
Yes |
| IC and Clocks | U172 | eMMC memory | N/A | 85 (C) 105 (I) |
Yes |
| U179 | PS supervisor | 150 | N/A | ||
| U181 | 150 | N/A | |||
| U183 | PL supervisor | 150 | N/A | ||
| Power Supplies | U167 | PMIC | 125 | N/A | Yes |
| U170 | 125 | N/A | Yes | ||
These thermal specifications are for simulation evaluations. The designed SOM thermal solution is expected to be sufficient to maintain the on board components within their maximum temperature limits as detailed in the table. Tj of the K24 SOM can be accessed during qualification test via the SYSMON.