An accurate power estimation is critical to defining an effective thermal solution and keeping the K24 SOM components below their maximum junction temperature (Tj). When designing the K24 SOM thermal solution, the worst-case power is the starting point for simulation. Once a thermal solution is defined and the Tj is within the limits, the theta JA (ϴJA) of the system can be input back into the PDM tool for a more accurate estimation of the power requirements for the K24 SOM.
Based on the temperature grade of the commercial temperature grade K24C SOM or the industrial temperature grade K24I SOM, the junction temperature should be forced to the maximum desired operating temperature (often maximum device operating temperature) to get the worst-case power estimation for the K24 SOM. The following example shows the K24C SOM when the Tj is forced to 85°C. The power dissipation of each of the components on the SOM is shown in the Thermal Loading table.
In this example:
- Tj is forced to the maximum allowed for the K24C SOM (85°C)
- Maximum process is selected to get the worst-case static power
- The thermal power of the SOM components
- Total electrical power required on the SOM 5V connector is based on the current estimation
The thermal loading in the PDM tool matches the components in the SOM thermal model, the thermal power for every component listed should be added. The PCB also has a small amount of power loss to account for an inductor or other ancillary components, this power should be applied to the PCB in the model.
Once a capable thermal solution is designed and validated in thermal simulation, the power estimation can be refined using the simulation results.
- Apply the calculated effective ϴJA of the system
in the PDM tool along with the maximum
supported Ta for the product. This is the recommended
approach because the power estimation dynamically estimates the anticipated
Tj and provides a more accurate estimated
power.Thermal Tip: ϴJA is a measure of how the junction temperature (Tj) will increase above the ambient temperature (TA) for every watt of power dissipated (Pd) in the device, the units are °C/W. ϴJA is calculated using the following equation: ϴJA = (Tj – TA)/ PD.
The following example shows a TA of 25°C with a ϴJA of 3.954°C/W and the estimate Tj based on the current estimation is 35.3°C, which is a more accurate total power estimation for the SOM. The total power at 35.3°C is 5.2W, compared to 6.5W at 85°C in the worst-case estimate.
Figure 3. Power Estimation Example
- Use the results of your initial estimation and thermal
simulations to constrain a Vitis or
Vivado design to keep the power of
the deployed application within the required power limits. As a minimum, use
the following constraints to report power for a correct analysis of the SOM
power and to accurately assess static and dynamic
power:
set_operating_conditions -design_power_budget <Power in Watts> set_operating_conditions -process maximum set_operating_conditions -ambient_temp <Max Supported by Application> set_operating_conditions -thetaja <Increase in Tj for every W dissipated C/W>