Table 1. K24 SOM Thermal Specifications
K24 SOM Operating Temperature
K24C SOM 0°C to 85°C
Metal enclosure (HSP-00098-01) C grade 0°C to 70°C maximum
Tip: The K24 is a production qualified SOM. For evaluation, the Kria KD240 Drives Starter Kit is available but is not intended for deployment. See Kria K24 SOM Data Sheet (DS985).

The K24 SOM has a metal enclosure. This metal enclosure makes full contact with all the high-power active components, including the Zynq UltraScale+ MPSoC, LPDDR4 memory, eMMC, power management integrated circuit (PMIC), and power regulators. The primary function of the metal enclosure is to transfer the non-uniform heat distribution of the module that is generated on the PCB assembly to the metal enclosure, making the heat flux more uniform and spread over a larger surface area. This allows for more efficient heat transfer out of the package to an attached thermal device. Any external thermal solutions added to user-defined systems should be directly attached to the top surface of the metal enclosure to properly maintain the operating temperature maximums.

Figure 1. K24 SOM

The metal enclosure has four M3 mounting holes on the corners to attach the appropriate thermal solution for your system. Further details are available in the Kria SOM Carrier Card Design Guide (UG1091). Your system thermal solution must provide adequate cooling to maintain all the components on the PCB, including the K24 SOM, below the maximum temperature specifications as detailed in Table 1.