The K24 SOM Zynq UltraScale+ MPSoC junction temperature (Tj) represents the die temperature read from either the PS or PL System Monitor sensors. The on-die thermal sensors are used for Tj management and many other temperature-dependent functions.
The on-die temperature sensors (System Monitor) of the Zynq UltraScale+ MPSoC on the K24 SOM are placed for a high accuracy measurement of the maximum junction temperature. To maintain the performance and reliability of the K24 SOM module, your design must be in compliance with the specifications in the following table.
| Parameter | SOM | Junction Temperature (Tj) |
|---|---|---|
| Maximum K24 SOM operating temperature 1 | K24C SOM | 85°C |
| K24I SOM | 100°C | |
| K24 SOM critical temperature 2 | K24C SOM | 90°C |
| K24I SOM | 105°C | |
|
||