Empirical Formula for the Metal Enclosure Temperature Rise
The following empirical formula is used to calculate the metal enclosure temperature rise:
Where:
- Metal Enclosure Temperature = Ambient Temperature + Metal Enclosure Temperature Rise
- R-SA is the thermal resistance of the cooling solution designed for your system, with TIM to ambient in °C/W.
- Power is the total SOM input power (W).
The following plot shows the deviation of the metal enclosure temperature rise obtained from the above correlation for different input system powers associated to the experimental values. The points represent experimental data while the solid lines show the correlation trend which aligns very well with the test points.
From this image you can use the correlation obtained from the estimated system power of your application and the target system thermal resistance of the solution installed on the K24 SOM metal enclosure to find the metal enclosure temperature rise.
Empirical Formula to Find the Temperature Rise between the SYSMON and Metal Enclosure
The following empirical formula is used to calculate the temperature rise between the K24 SYSMON and the metal enclosure:
Using the correlation with the target system power, the expected temperature rise between the K24 SOM SYSMON and metal enclosure can be calculated.
Illustrations of Applying the Empirical Correlations
In this first example, the system is operated at 35°C ambient, with a total estimated power of 10W and the thermal resistance of a cooling solution is 5°C/W. The SYSMON temperature is obtained by using the correlations outlined earlier in this section. Using the Empirical Formula for the Metal Enclosure Temperature Rise:
The result of this example is that with the estimated SYSMON temperature obtained from the empirical relations, you can verify whether your selected thermal solution meets the K24 SOM thermal specifications list in Table 1.
The second example has an estimated system power of 10W when operating in 25°C ambient temperature, the maximum SYSMON temperature is specified as 85°C. Using the correlations outlined earlier in this section, an estimated thermal resistance from metal enclosure to ambient (R-SA) is calculated, defining an appropriate thermal solution as:
K24 SOM Stand-alone and Exposed to Air
In a K24 SOM system where the metal enclosure is exposed to air, the recommended clearance above the metal enclosure is approximately 30 mm. In this case, it is anticipated that the thermal resistance from the metal enclosure to the ambient would be in the range of ~9 to 10°C/W. This arrangement can produce limited performance where the dissipated power from K24 SOM is smaller. It is crucial that K24 SOM is operating in a system arrangement that keeps the SYSMON temperature below the specification outlined in Table 1.
For example, a K24 SOM with a metal enclosure that has a thermal resistance from the metal enclosure to an ambient temperature of 9°C/W. The area surrounding the K24 SOM in 30 mm of free area is 35°C, and the maximum SYSMON temperature specified from the specification is 100°C. Under this condition, the maximum dissipated power from the K24 SOM is described in the following formulas:
Calculating the sum of the two equations:
Solving this equation gives Power = 6.9W.