MIN_VCC_PSINTLP (PSSYSMON) Register - MIN_VCC_PSINTLP (PSSYSMON) Register - UG1087

Zynq UltraScale+ Devices Register Reference (UG1087)

Document ID
UG1087
Release Date
2025-06-20
Revision
1.11

MIN_VCC_PSINTLP (PSSYSMON) Register Description

Register NameMIN_VCC_PSINTLP
Offset Address0x0000000094
Absolute Address 0x00FFA50894 (AMS_PS_SYSMON)
Width16
TyperoRead-only
Reset Value0x0000FFFF
DescriptionMin voltage measured for VCC PS LPD (supply1).

MIN_VCC_PSINTLP (PSSYSMON) Register Bit-Field Summary

Field NameBitsTypeReset ValueDescription
supply_val15:0roRead-only0xFFFFMinimum value recorded in the voltage measurement register since the last reset. Read-only. Cleared by unit reset.