MAX_VUSER2 (PLSYSMON) Register Description
| Register Name | MAX_VUSER2 |
|---|---|
| Offset Address | 0x0000000288 |
| Absolute Address | 0x00FFA50E88 (AMS_PL_SYSMON) |
| Width | 16 |
| Type | roRead-only |
| Reset Value | 0x00000000 |
| Description | Max voltage measured for VUser2 (supply9). |
MAX_VUSER2 (PLSYSMON) Register Bit-Field Summary
| Field Name | Bits | Type | Reset Value | Description |
|---|---|---|---|---|
| supply_val | 15:0 | roRead-only | 0x0 | Maximum value recorded in the Voltage measurement register since the last reset. Read-only. Cleared by unit reset. |