MAX_VCC_PSINTLP (PSSYSMON) Register - MAX_VCC_PSINTLP (PSSYSMON) Register - UG1087

Zynq UltraScale+ Devices Register Reference (UG1087)

Document ID
UG1087
Release Date
2025-06-20
Revision
1.11

MAX_VCC_PSINTLP (PSSYSMON) Register Description

Register NameMAX_VCC_PSINTLP
Offset Address0x0000000084
Absolute Address 0x00FFA50884 (AMS_PS_SYSMON)
Width16
TyperoRead-only
Reset Value0x00000000
DescriptionMax voltage measured for VCC PS LPD (supply1).

MAX_VCC_PSINTLP (PSSYSMON) Register Bit-Field Summary

Field NameBitsTypeReset ValueDescription
supply_val15:0roRead-only0x0Maximum value recorded in the voltage measurement register since last reset. Read-only. Cleared by unit reset.