In this stage of calibration, the duty cycle of WCK (write DQS in LP5) is adjusted to correct any duty cycle errors. For various reasons, WCK is subject to systematic duty cycle errors resulting in incorrect reads and writes.
Duty cycle monitoring is enabled via MR commands to read out the duty cycle status. Based on the status, the duty cycle adjuster (DCA) is set accordingly to achieve the optimal setting.