Host SidebandBus Clock (HSCL) and Host SidebandBus Data (HSDA) connect from the Versal PMC I2C interface to the HUB device on each DIMM. These signals carry the I2C (or I3C) sideband traffic for PMIC and RCD initialization.

The HSCL and HSDA signals can operate at 1.0V or 1.8V:

1.0V operation
Enables I3C compatibility on the DIMM side.
1.8V operation
Restricts DIMM-side operation to I2C mode only.

Because the Versal PMC IO can operate at a different voltage level, the HSCL/HSDA signal path might require a level shifter to step down to 1.0V or 1.8V. If you use a level shifter, follow these guidelines:

  • Place 2.2 kΩ pull-up resistors on HSCL and HSDA at the RDIMM side of the level shifter.
  • Do not place any multiplexors in the HSCL/HSDA path — the PMC cannot control them during boot and device configuration.

Refer to JESD300-5B.01, JESD403-1C.01, and the Versal Adaptive SoC PCB Design User Guide (UG863) for complete electrical requirements.