Output Interface Ports - Output Interface Ports - 1.0 English - PG441

MIPI DSI-2 Receiver Subsystem LogiCORE IP Product Guide (PG441)

Document_ID
PG441
Release_Date
2026-07-27
Version
1.0 English
Table 1. Output Interface Ports
Signal Direction Clock Domain Description
AXI4-Stream Video Interface
video_out_tvalid Output video_aclk Assert High when valid data is available on video_out_tdata bus.
video_out_tready Input video_aclk Consumer ready to accept the data
video_out_tlast Output video_aclk Assert high when the line end.
video_out_tdata [N-1:0] Output video_aclk AXI4-Stream video data. Width (N) depends on the Pixel format and Pixel mode. The details are given below in this table.
  • 1 PPC: N = 24
  • 2 PPC: N = 48
  • 4 PPC: N = 96
Note: More details available in section Pixel Decoding.
video_out_tkeep[(N/8)-1:0] Output video_aclk Indicates valid bytes.
video_out_tuser [15:0] Output video_aclk

Sync events Short packet payload is mapped to this bus.

  • bits [15:8] - Data1
  • bits [7:0] - Data0
video_out_tdest [7:0] Output video_aclk

Data type and Fixed VC is mapped to this bus.

  • bit [7:6] - Fixed VC
  • bit [5:0] - Data type
vss Output video_aclk Vertical Sync Start pulse output
vse Output video_aclk Vertical Sync End pulse output
hss Output video_aclk Horizontal Sync Start pulse output
hse Output video_aclk Horizontal Sync End pulse output
Command Interface
cmd_gnrc_data [N-1:0] Output video_aclk

This signal gives the command/generic packet data. If cmd_valid is set the data on this bus indicates the DCS command data. If gnrc_long_valid is set, it is generic long packet data.

  • short write payload [byte1, byte0] – cmd_gnrc_data [15:0]
  • Long write command – same width as video_out_tdata

For the command short/long write type, refer to cmd_short_pkt_vld port details.

Width of this bus is same as video_out_tdata.

Command Interface Timing Diagrams shows the Command Interface Timing waveform for different configurations.

cmd_valid Output video_aclk This port value is set to high when valid command data is available on cmd_gnrc_data.
cmd_gnrc_keep[(N/8)-1:0] Output video_aclk Indicates valid bytes in cmd_gnrc_data.
cmd_gnrc_last Output video_aclk Indicates last bytes of DCS or Generic long packet.
cmd_short_pkt_vld Output video_aclk

This signal indicates the current packet is of short write or long write when cmd_valid is set to high.

  • 1 – Short write
  • 0 – Long write
cmd_gnrc_header [7:0] Output video_aclk

Used for command data type indication.

For example, DCS Short write with 0 parameter, data type is 0x05. when this command is sent, the signal value set to 0x05.

  • bit [7:6] - Fixed VC
  • bit [5:0] - Data type
gnrc_long_valid Output video_aclk This signal is set to high when valid generic long packet is available on cmd_gnrc_data.
Other signals
dsirxss_dsi_irq Output cnts_byteclk System interrupt output
clkoutphy_out Output NA PHY serial clock
pll_lock_out Output NA PLL lock indication (active-High)
system_rst_out Output NA Reset indication due to PLL reset (active-High)
rxbyteclkhs_cnts_out Output NA Continuous PPI high-speed receive byte clock
Init_done_out Output NA An active-High signal which indicates lane initialization is done
rxbyteclkhs Output NA PPI high-speed receive byte clock