The Programmable Sequence data1 register is used to send the symbols 10 to 13 of programmable sequence. The following table provides the register bit description. This register is used in C-PHY configuration only.
| Bits | Name | Default Value | Access type | Description |
|---|---|---|---|---|
| [31:12] | Reserved | 0x0 | RO | Reserved |
| [11:9] | prog_seq_data13 | 0x3 | R/W | S13 in the Programmable Sequence
Values: 0 to 4: Symbol value 5 to 7: Invalid value, not a valid symbol value. |
| [8:6] | prog_seq_data12 | 0x3 | R/W | S12 in the Programmable Sequence Values: 0 to 4: Symbol value 5 to 7: Invalid value, not a valid symbol value. |
| [5:3] | prog_seq_data11 | 0x3 | R/W | S11 in the Programmable Sequence Values: 0 to 4: Symbol value 5 to 7: Invalid value, not a valid symbol value. |
| [2:0] | prog_seq_data10 | 0x3 | R/W | S10 in the Programmable Sequence Values: 0 to 4: Symbol value 5 to 7: Invalid value, not a valid symbol value. |