The Programmable Sequence data0 register is used to send the symbols 0 to 9 of programmable sequence. The following table provides the register bit description. This register is used in C-PHY configuration only.
| Bits | Name | Default Value | Access type | Description |
|---|---|---|---|---|
| 31:30 | Reserved | 0x0 | RO | Reserved |
| 29:27 | prog_seq_sym9 | 0x3 | R/W | S9 in the Programmable Sequence
Values: 0 to 4: Symbol value 5 to 7: Invalid value, not a valid symbol value. |
| 26:24 | prog_seq_sym8 | 0x3 | R/W | S8 in the Programmable Sequence Values: 0 to 4: Symbol value 5 to 7: Invalid value, not a valid symbol value. |
| 23:21 | prog_seq_sym7 | 0x3 | R/W | S7 in the Programmable Sequence Values: 0 to 4: Symbol value 5 to 7: Invalid value, not a valid symbol value. |
| 20:18 | prog_seq_sym6 | 0x3 | R/W | S6 in the Programmable Sequence Values: 0 to 4: Symbol value 5 to 7: Invalid value, not a valid symbol value. |
| 17:15 | prog_seq_sym5 | 0x3 | R/W | S5 in the Programmable Sequence Values: 0 to 4: Symbol value 5 to 7: Invalid value, not a valid symbol value. |
| 14:12 | prog_seq_sym4 | 0x3 | R/W | S4 in the Programmable Sequence Values: 0 to 4: Symbol value 5 to 7: Invalid value, not a valid symbol value. |
| 11:9 | prog_seq_sym3 | 0x3 | R/W | S3 in the Programmable Sequence Values: 0 to 4: Symbol value 5 to 7: Invalid value, not a valid symbol value. |
| 8:6 | prog_seq_sym2 | 0x3 | R/W | S2 in the Programmable Sequence Values: 0 to 4: Symbol value 5 to 7: Invalid value, not a valid symbol value. |
| 5:3 | prog_seq_sym1 | 0x3 | R/W | S1 in the Programmable Sequence Values: 0 to 4: Symbol value 5 to 7: Invalid value, not a valid symbol value. |
| 2:0 | prog_seq_sym0 | 0x3 | R/W | S0 in the Programmable Sequence Values: 0 to 4: Symbol value 5 to 7: Invalid value, not a valid symbol value. |