PROGRAMMABLE SEQUENCE DATA0 Register (0x3C) - PROGRAMMABLE SEQUENCE DATA0 Register (0x3C) - 1.0 English - PG436

MIPI TX C-PHY/D-PHY LogiCORE IP Product Guide (PG436)

Document ID
PG436
Release Date
2025-11-20
Version
1.0 English

The Programmable Sequence data0 register is used to send the symbols 0 to 9 of programmable sequence. The following table provides the register bit description. This register is used in C-PHY configuration only.

Table 1. Programmable Sequence Data0 Register Bit Description
Bits Name Default Value Access type Description
[31:30] Reserved 0x0 RO Reserved
[29:27] prog_seq_sym9 0x3 R/W S9 in the Programmable Sequence Values:

0 to 4: Symbol value

5 to 7: Invalid value, not a valid symbol value.

[26:24] prog_seq_sym8 0x3 R/W S8 in the Programmable Sequence Values:

0 to 4: Symbol value

5 to 7: Invalid value, not a valid symbol value.

[23:21] prog_seq_sym7 0x3 R/W S7 in the Programmable Sequence Values:

0 to 4: Symbol value

5 to 7: Invalid value, not a valid symbol value.

[20:18] prog_seq_sym6 0x3 R/W S6 in the Programmable Sequence Values:

0 to 4: Symbol value

5 to 7: Invalid value, not a valid symbol value.

[17:15] prog_seq_sym5 0x3 R/W S5 in the Programmable Sequence Values:

0 to 4: Symbol value

5 to 7: Invalid value, not a valid symbol value.

[14:12] prog_seq_sym4 0x3 R/W S4 in the Programmable Sequence Values:

0 to 4: Symbol value

5 to 7: Invalid value, not a valid symbol value.

[11:9] prog_seq_sym3 0x3 R/W S3 in the Programmable Sequence Values:

0 to 4: Symbol value

5 to 7: Invalid value, not a valid symbol value.

[8:6] prog_seq_sym2 0x3 R/W S2 in the Programmable Sequence Values:

0 to 4: Symbol value

5 to 7: Invalid value, not a valid symbol value.

[5:3] prog_seq_sym1 0x3 R/W S1 in the Programmable Sequence Values:

0 to 4: Symbol value

5 to 7: Invalid value, not a valid symbol value.

[2:0] prog_seq_sym0 0x3 R/W S0 in the Programmable Sequence Values:

0 to 4: Symbol value

5 to 7: Invalid value, not a valid symbol value.