This section describes trigger transmission operation.
-
txrequestescis asserted along with the trigger value intxtriggeresc[3:0]. - Because the PPI does not have a handshake signal to report back the trigger
transmission on the serial line,
txrequestescis driven Low after 30txclkescclock cycles. The 30 clock cycles ensure that the MIPI TX C-PHY/D-PHY core transfers the trigger command on the serial line.
The following figure shows the trigger transmission operation.
Figure 1. Trigger Command Transmission from D-PHY TX