The Trace PIB Implementation Register is only implemented when external trace is enabled (C_TRACE_OUTPUT = 1).

Reserved CompType VerMinor VerMajor
31 12 11 8 7 4 3 0
Table 1. Trace Funnel Implementation Register Bit Definitions
Bits Name Access Reset Value Description
31:12 - R 0 Reserved
11:8 trPibCompType R 1010 Trace PIB Sink Component type
7:4 trPibVerMinor R 0000 Trace PIB Sink Component Minor Version
3:0 trPibVerMajor R 0001 Trace PIB Sink Component Major Version